毛片网站视频久久午夜一区二区91香蕉成人免费网站欧美成人三级网站_无无精品国产v日韩v亚洲爆乳_亚洲国欧美日韩产一区二区精品区_欧美特黄一级片免费在线观看_丝瓜草莓秋葵榴莲绿巨人软件

Whats app/ Zalo/ Wechat/ Telephone:0086-18575511218

E-mail: sales@roc-ele.com / info@roc-ele.com

Contact Us

 ROC Precision Intelligent Technology Co., Ltd.

Industrial Cleaning

Your current location: HOME > Industrial Cleaning >

ROC-250L DI water treatment machine

  • Category:Industrial Cleaning

  • The number of clicks:
  • Release date:2020-05-06
  • 在線詢價
  • Detailed introduction

 

Name: Deionized water treatment equipment

 

Brand: ROC 

 

Model: ROC-250L

 

It is finished with filtration system such as filter cotton, quartz sand, water activated carbon, RO membrane and polishing resin. The export resistivity can reach above 10 megaohms to ensure the quality of water.

 

I. Deionized water treatment equipment ROC-250L Application areas:

Deionized water treatment equipment ROC-250L: Fully automatic completion of the entire integration process from municipal water---pure water---deionized water.

Application: According to the user's technical requirements, water quantity and other technical indicators, the customer group with high requirements for water quality cleaning such as semiconductor and optics is designed and provided based on the municipal tap water quality, and this RO reverse osmosis + MB mixed bed ultrapure water is designed and provided. Preparation system.

The ultrapure water system can be divided into three major components according to its composition function: pretreatment system, RO reverse osmosis system, MB mixed bed system; multi-media filter (quartz sand, coconut shell activated carbon), cationic softener And pp cotton core fine filter composition; its function is to remove particulate impurities, organic matter, residual chlorine, etc. in raw water, reduce the SDI value of water, prevent calcium and magnesium ions in water from scaling on reverse osmosis membrane, and protect the back end process The RO membrane system in the long-term stable operation. According to the requirements of RO reverse osmosis water production, the pre-treatment standard effluent capacity is designed to be 1m3/h. RO reverse osmosis system: mainly consists of high pressure pump, reverse osmosis membrane, membrane pressure vessel assembly and so on. It acts as a pre-desalting effect on water. The removal rate of raw water salt content is above 98%. Considering the natural aging change of the reverse osmosis membrane over time, the configuration has a margin, and the standard water production of reverse osmosis is 250L/h. The water production of the terminal MB mixed bed system is 0.5 ton/hour (normal temperature).

Water quality: RO reverse osmosis system The desalination rate is greater than 98%, and the terminal effluent resistivity reaches 10-15 MΩ/CM for cleaning process water (25`C).

Raw water quality: local municipal tap water.

 

Second, deionized water treatment equipment ROC-250L system structure:

 

Pre-processing system:

Including multi-media filter (quartz sand, coconut shell activated carbon) PP cotton core fine filter.

1.1, multi-media filter

1.2. Suspended matter in water is smaller particles. It can be seen by the naked eye that these particles are mainly composed of sediment, clay, protozoa, algae, bacteria, and high molecular organic matter, and are often suspended in water. When the tap water passes through the quartz sand, the large-particle suspension activated carbon can remove the aquatic organisms, plants or microbes in the water, and the scent or smell of the fishy smell and the odor of the organic matter. Residual chlorine remaining in disinfectant water. Ensure the normal operation of subsequent systems. The reduction of residual chlorine in the water plays a significant role in the protection of the softened resin and the membrane module, prolonging the service life of the reverse osmosis membrane and the mixed bed.

2.1, flush multi-media filter: (flushing cycle: 1-2 times a week, depending on local water quality)

        Flushing method: The multi-media filter is manually controlled to the normal flushing position, after 15 minutes of flushing, it is dialed to the positive punching position, and then rinsed for 10 minutes. After the flushing is completed, the multi-way valve is set to the running state.

3.1, cationic softener

         In order to prevent the precipitation of calcium and magnesium ions in the water on the reverse osmosis membrane, the membrane module is damaged by the solid particles, and large-scale scaling occurs. Adding a softener before R.O reverse osmosis can extend the system cleaning cycle limit and extend the life of the membrane to reduce costs. Rinse the regenerative cationic softener (cycle: depending on the water quality) as follows:

(a) first add 5 kg of industrial salt in an industrial salt tank, and add 15 kg of saturated solution by adding water;

(b) Backwashing: Turn the manual multi-way valve to the backwash position (BACK WASH) for 15 minutes and then dial to the aspiration position (BRINE&SLOWR);

(c) Brine suction: After the manual multi-way valve is set to the salt absorption position (BRINE&SLOWR), the salt water is automatically sucked (20-25 minutes);

(d) Quick flushing: After sucking 20 kg of industrial salt solution, the manual multi-way valve is set to the fast flushing position (FAST RINSE) for 30 minutes;

(e) Sampling test: Open the sampling valve to take out the sample water. It is required to use the special demineralized water reagent to determine the test. The softened water is sampled and the reagent is added. If the color of the sample water turns blue, it is acceptable. If it is purple or red, it is bad. Regeneration cleaning. After the cleaning is completed, the normal water supply (SERVICE) is performed.

 

Second, deionized water treatment equipment ROC-250L system structure:

RO reverse osmosis system:

RO reverse osmosis unit is the heart of the whole set of pure water system. Users should pay special attention to maintenance. Usually, when the RO system is running, the operation data should be adjusted according to the design reference values ??of the system. When adjusting, the membrane water output and working pressure are the main indicators, and the membrane is blocked and contaminated. The inlet pressure, the outlet pressure, the influent flow, the outlet flow, and the pure water conductivity should be recorded normally so that the system can be faulty to find out the cause. In general, the removal rate of organic matter by the RO pure water system can reach 99.9%. For inorganic salts, it can reach 94%~98%. Since the RO system has the fine ability of high-efficiency deionization, the resistance of the water can be compared with the resistance of the water inlet and the outlet of the system to obtain the working efficiency. The ability of the RO system to remove minerals and organic matter can maintain stable water quality due to periodic flushing and drug washing operations.

The machine operation data is based on the following factors:

1) The inlet water temperature is maintained within the design range (about 25 ° C at room temperature)

2) The water index should be the same as the municipal tap water when entering the water.

3) Inlet water must pass through pre-treatment equipment to reduce SDI and remove residual chlorine. The RO system uses automatic control technology and has the necessary protection, such as water shortage, full water, low pressure protection, etc., but does not mean the system. It can be operated unattended for a long time. Please record the pressure, flow, temperature and conductivity parameters regularly. When the limit of the system is designed, please adjust it in time. Otherwise, the RO membrane or system will be damaged, which will affect the service life of the machine. . Therefore, it is recommended that users operate and record in strict accordance with the design specifications. The company has the right to bear no responsibility for losses caused by personnel errors and unfavorable supervision.

Second, deionized water treatment equipment ROC-250L system structure:

In vitro regenerative mixed bed system:

4.1 RO water tank

       The RO water tank is placed behind the RO unit to store RO water and buffer, which provides sufficient and stable water for the mixed bed system.

4.2 DI pure water pump

       The DI pure water pump supplies the pressure and flow required for the normal operation of the external regenerative mixing bed unit;

4.3 MB mixed bed

       Although single-stage reverse osmosis has removed most of the ions, it still does not meet the water quality requirements of ultrapure water. Therefore, a two-stage mixed bed is used for fine desalting. The two-stage mixed bed process is used for fine desalting to obtain qualified pure water. According to the water consumption of the washing machine and the water quality of the user's location, the terminal mixed bed is replaced once every six months or so (depending on the water quality requirements).

 PP fine filter:

       The security filter is the last filter device before entering the R.O reverse osmosis host. It must ensure that the pollution index SDI of the tap water before entering the reverse osmosis host is stable below 4. Since the pure water recovery rate of the reverse osmosis unit is generally only 50%-60%, the designed water production is 1t/h.

       Operating principle:

      (a) The PP cotton filter adopts a 5um-diameter PP cotton filter. The water permeates from the PP cotton and permeates through the micropores from the central tube of the PP cotton inner wall, thereby filtering out fine particles impurities larger than the pore diameter.

      (b) After a period of use of PP cotton, more and more foreign particles are trapped outside the outer hole until it fails. At this time, please replace the filter element, otherwise it will pollute the subsequent reverse osmosis equipment. The general replacement period is 1-2. Months (depending on local water quality and water use).

 

 

 

 

 

Fourth, deionized water treatment equipment ROC-250L Features:

1, with 24 small continuous water production function, the salt removal rate is as high as 97% or more;

2. It has a fast low-pressure flushing to replace the residual water in reverse osmosis. All these measures aim to reduce the frequency of chemical cleaning and disinfection and prolong the service life of reverse osmosis membrane;

3, fully automatic operation, once the water source is insufficient, it has a shutdown protection function;

4. The reverse osmosis outlet pressure is high, and the reverse osmosis system will also be shut down. If the reverse osmosis inlet pressure is too low, the reverse osmosis system will also be shut down. After the reverse osmosis tank water level is full, the reverse osmosis system will also stop;

5, the system has a low-voltage power-off automatic protection function, when the high-pressure pump inlet water pressure is reduced to the limit, the RO high-pressure pump will automatically stop, so as to avoid damage to the high-pressure pump, and the system will issue a prompt (the original water low-pressure lamp is off);

6. The RO system has an automatic water supply device. When the liquid level of the RO storage tank reaches a low water level, the system automatically starts. When the liquid level of the RO storage tank reaches a high water level, the RO system automatically stops;

7. The system also has a complete automatic flushing function, with fast and low pressure flushing at startup, which reduces the speed of contamination of the reverse osmosis membrane system, prolongs the cycle of chemical cleaning of the reverse osmosis membrane and the service life of the reverse osmosis membrane;

Deionized water treatment equipment ROC-250L Parameters